OP5511 - High Voltage and High Current input conditioning module
The High-current and high-voltage input conditioning module allows the conversion of 4 current and 4 voltage signals to ±10V voltage level. The current inputs are factory configurable for up to 50A continuous. The measured voltage range is configurable for up to 600 volts. Such modules are typically used for monitoring current and voltage on DC motors. |
|
| Contact sales for more Info | Request a Live Online DemoThis is a request to schedule an Online Demonstration of OP5511 - High Voltage and High Current input conditioning module with an Opal-RT Representative. | Share Product | |
Features
- 4 current-measurement inputs, factory configurable for up to 50 amps continuous.
- 4 voltage-measurement inputs, jumper configurable from 50 volts to 600 volts range
- Rugged screw terminal connections
- Compatible with Opal-RT OP5340 analog input module
- Activity and out-of-range LEDs for each channels
The front panel has activity and out-of-range LEDs for each channel. For current-measurement channels, the activity LED (green) turns on when a current above 200mA is detected, while the out-of-range LED (red) turns on when the current limit has been reached. For voltagemeasurement inputs, the activity LED turns on at 2V, while the out-of-range LED turns on when one of the voltage limits is reached.

Current sensor channel
- Input range: factory setting (available in 5, 15, 25 and 50 amps)
- Signal output range: ± 10 volts
- Isolation: galvanic, 2.5 kV
- Bandwidth: DC to 100 kHz
- Linearity: < 0.2%
- Rise time: < 2 microseconds
- Power supplies: ±15 volts
Voltage sensor channel
- Input range: jumper-selectable (50, 100, 200, 400, and 600 volts)
- Signal output range: ± 10 volts
- Common mode: greater than 200 volts after the resistive divider
- Bandwidth: DC to 100 kHz
- Linearity: < 0.2 % Rise time: < 2 microseconds
- Power supplies: ±15 volts
Casing
- Physical dimensions: 6.3" x 6.3" x 2.0"
No Data Available
No Data Available